3E1-V.35 IDM-OPT4E1V PCM multiplexer FXO/FXS Audio Optical Multiplexer User’ Manual

IDM-OPT3E1V multiplexer use very large scale integrated circuit development point-to-point optical transmission equipment, it with concise form of veneer for up to 4 E1 business mix reuse and 2 Ethernet data sharing 100 m wire speed of light transmission and v. 1 road 35 interface. E + E optical transceiver equipment management this equipment by bureau of end, alarm monitoring function is perfect, high integration, low power consumption, stable performance, convenient use, etc.
Contact Us

 

 

 

 

IDM-OPT4E1V

 

 

 

 

User Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To User:

(1)                      Thank you use my company's products. Within the scope of this equipment is used in the design has good and reliable performance, but still should avoid man-made damage to the equipment damage or. Before using this product, please read this user manual carefully, and properly kept, for reference.

(2)                      Before installing this product, please check the model, and installed according to the requirements of user manual.

(3)                      Do not make this product in the rain or be affected with damp be affected with damp in order to avoid damage.

(4)                      Don't put anything on the power cable, the cable tie or encase.

(5)                      The power adapter, and other equipment shall be connected to each other tightly fitting, please check.

(6)                      Please note that the equipment clean, if necessary, can use soft cotton cloth to wipe.

(7)                      Please note that don't block ventilation cooling hole.

(8)                      Please don't repair equipment, except there are clear instructions in the manual. When the equipment running abnormal please power off immediately and contact the company's after-sales service.

 

 

 

 

 

 

System Introduction

Overview

IDM-OPT3E1V multiplexer use very large scale integrated circuit development point-to-point optical transmission equipment, it with concise form of veneer for up to 4 E1 business mix reuse and 2 Ethernet data sharing 100 m wire speed of light transmission and v. 1 road 35 interface. E + E optical transceiver equipment management this equipment by bureau of end, alarm monitoring function is perfect, high integration, low power consumption, stable performance, convenient use, etc.

When the equipment selection 4-way E1 business, v. 35 interface cannot be used. That this equipment is divided into two kinds. 

Main feature

Ø                      Can provide up to 4 E1 transparent transmission, at the same time provide two Shared line speed of 100 m Ethernet channel

Ø                      Optical rate of 155 MBPS, transmission distance of 20 Km, 40 Km, 60 Km, 80 Km is optional

Ø                      E1 interface type for HDB3 code, E1 shake limit, transfer characteristic, output jitter arouses fully conforms to the ITU-T G.703, G.823 and G.742

Ø                      Can through the network of the center side configuration VLAN function, support the flow control function

Ø                      Have complete alarm function, and can be real-time monitoring to the end state of the equipment

Ø                      Support the E1 branch the bidirectional ring back to function

Ø                      Provide v. 35 interface, the line rate n * 64 kbit/s (n = 1 ~ 32) can be set up through the network management

Ø                      V. 35 interface into the frame model can be set to PCM30 or PCM31 mode

 

IDM-OPT3E1V Complete with the alarm monitoring functions. The alarm content include optical disappear, out-of-frame, 10-3, 10-6 error code, each E1 branch Interrupt signal and Ethernet interface instructions. In addition to report on this end alarm status, can also pass a dial the code, using the light show of the alarm status on this. 

 

Application

Point to Point Network

 

img1

2-1 application 1

Network with centralized

img2

2-2 Application 2

V.35 interface timing mode setting up

Setting principleIn the whole line, only have one clock source, it is master clock.

 

img3

3-1 Application 1

img4

3-2 Application 2

Loopback using 

 

4-1 LOOP application

Note: When V.35 is framing, the loopback is used to the slot.

Specifications

 

Optical interface

Rate

155Mbps±50ppm

Wavelength

1310nm/1550nm

Physical connector

FC/SC

Sensitivity

Better than -36dBm

 

E1 interface

Channels

4

Rate

2.048Mbps±50ppm

Comply with

ITU-T G.703

Code

HDB3

Impedance

75 unbalanced and 120 balanced

 

Ethernet interface

Rate

100Mbps, 10M/100M auto-negotiation

Comply with

IEEE802.3, 10/100Base-TX

Duplex

Full/Half auto-negotiation

 

Power Supply

220VAC/-48VDC

Consumption: 40W±10%

 

Operating Environment

Temperature: 0ºC~40ºC

Humidity: 90% (non- coagulation)

 

Dimensions

440mm×230mm×45mm (Width × Depth × Height)

 

Operating instructions

Front panel

img5

4-1 Front panel 

Form 1

Name

Color

State

Function description

POW

Green

On

Optical power indicator

When normal power, After switch the power , the light is on

NOP

Red

On

Matt detection indicator. The alarm will shield LOF, IE-3, IE-6 alarm

When the device detects no light input optical port, the light is on

When the device detects that the light received by the optical interface, the light is off

After pressing the alarm selector switch, terminal alarm NOP can be displayed on the NOP indicator

LOF

Red

On

Optical line group road frame stall, Alarm shielding IE-3, IE-6 alarm

When Matt, The alarm is masked. Valid alarm, Masked error alarm

After pressing the alarm selector switch, terminal alarm LOF can be displayed on the LOF indicator

E-3

Red

On

Line error is greater than 10-3 Alarm, The alarm will alert shield IE-6

After pressing the alarm selector switch, terminal alarm 10-3 can be displayed on the IE-3 indicator

E-6

Red

On

Line error is greater than 10-6 Alarm

After pressing the alarm selector switch, terminal alarm 10-6 can be displayed on the IE-6 indicator

LOS1-LOS4

Red

On

1 to 4 channel E1 tributary signal loss alarm indication

When E1 tributary signal loss, LOS indicator light corresponding branch

After pressing the alarm selector switch, terminal alarm LOF can be displayed on the LOF indicator

SPD1-SPD2

Green

On

100M Ethernet

Off

10M Ethernet

LINK1-LINK2

Green

Shiny

100M connection

Off

10M connection

TD

Green

Shiny

V.35 send Indicator: V.35 interface flashes when sending data

RD

Green

Shiny

V.35 received Indicator: V.35 interface flashes when data is received

 

Rear panel

img64-2 Rear panel

Form 2 Rear panel 

Type

Spec

Power

Provide AC220V/DC-48V

Optical interface

FC interface, 1310nm wavelength.

OUT1~3

1~3channels E1 output interface, 75Ohm.

IN1~4

1~3channels E1 input interface, 75Ohm.

ETH1-ETH2

Ethernet interface

 

img7

 

4-3 RJ45interface

Form 4 Interface pinout

RJ45

F interface

RS232 interface

E1 interface

 

 

 

1

 

 

OUT

2

 

 

OUTA

3

 

 

 

4

GND

TXD

IN 

5

TXD 

RXD

INA

6

RXD

 

 

7

 

GND

 

8

 

GND

 

 

Installation and Maintenance

6.1 Matters Need Attention in Erection

This series of equipment built-in precision components, please handle with care to avoid severe vibration, so as not to affect the device performance. If you find the equipment was damaged in transit or any parts are missing, please notify the company's after-sales service, we will give you proper solution as soon as possible. Please note that when you open the package directions, ensuring face-up, so as not to lose accessory bag.

Check equipment and accessories in accordance with the packing list. Please note that the inspection and check whether it is consistent with the packing list.

Safekeeping the network configuration diagram order to reference during installation and maintenance.

The machine is mounted on 19-inch standard rack or cabinet. Equipment should be opened at will tighten the screws on the panel. Necessary equipment should be installed in the lower bracket to support the weight of the equipment.

Please be careful not to plug the device left and right ventilation holes.

Please note that don't have other impurities inside the chassis. When the equipment into the dust with a soft cloth to wipe.

6.2 Installation

Please put the device in the specified location when the device is installed on the cabinet mounting bracket tray, positioning the mounting ear holes in the cabinet rack positioning holes.

Be sure that straight, smooth when loading. If there is block, pallets or equipment should be checked whether the deformation occurs, not use brute force forced into the device, so as not to damage equipment.

1)       Push device fully into the cabinet, make the earmuffs positioning hole and rack installation bracket positioning hole, tighten the rack screws, reliable fixed equipment and cabinets;

2)       Connect the power cord;

Equipment Standard models configured as DC-48V power supply or AC220V, before the device is plugged in, measure whether access within the required range of equipment and power supply voltage power first;

a) -48V Power supply: -48V ± 10%;

b) AC220V Power supply: Standard AC220V ± 20%, 50Hz

3Before the introduction of the power to the device, check the device's power switch is placed in OFF, if not, place it in the OFF

4Check -48V power line, GND (workplace) line, PGND (protected) line access is correct, whether the reverse polarity. How the device is properly connected to the power supply: low potential equipment -48V 48V power supply terminal and the engine room is connected to the high potential GND terminal equipment connected with 48V power supply room, PGND terminal is connected with the protected room.

5There is a protective earth terminals after the lower left panel of the chassis, leave this terminal connected with protected area of machine room!

Note: The working and protected area of the device is separate, protected area and chassis are connected. The working and protected can be connected on power connections on backplane if it is needed. Make sure to solve problems common ground.

6) Ground technical advice: chassis housing of the equipment should be connected to protective ground. If the central office can provide working and protected area separately, the working and protected area should access to the appropriate ground copper bars. If the central office only provides one ground copper bars, the working and protected area of the equipment joint ground is allowed. Grounding resistor should work to meet the DC grounding resistance, less than 4Ω.

img8

GND (power supply ground) and PGND (protective earth) of the equipment must be connected, connect the power cord only after confirming that the power line is connected correctly. If an exception occurs immediately after power, please off it, check and eliminate!

 

Appendix 

Ethernet

Ethernet cable have two kinds: one is cross line, another is through line. When Device connect PC should use cross line, when connect switch, should use through line

Through line: The pinout is the same both site. 

Cross line:

img9

1 T568A Twisted-pair cable cross line

V.35 Pinout

DB25 V.35 PIN

 

img10

2 DB25 PIN

Sequence number

DB25 (M)

 

Signaldefinition

Signal source

1

2

 

Transmit data (a)

DTE

2

14

 

Transmit data (b)

DTE

3

3

 

Receive data (a)

DCE

4

16

 

Receive data (b)

DCE

5

4

 

Request to send

DTE

6

5

 

Clear to send

DCE

7

6

 

Data set ready

DCE

8

20

 

Data terminal ready

DTE

9

8

 

Carrier detect

DCE

10

24

 

External Transmit Clock (a)

DTE

11

11

 

External Transmit Clock (b)

DTE

12

15

 

Transmit Clock (a)

DCE

13

12

 

Transmit Clock (b)

DCE

14

17

 

Receive Clock (a)

DCE

15

9

 

Receive Clock (b)

DCE

16

1

 

Frame ground

 

17

7

 

Signal ground

 

18

22

 

Ring Indicator