HOME    PDH Optical Multiplexer    IDM-300ME PDH Optical Multiplexer Multiservice Transmission Platform User'Manual

IDM-300ME PDH Optical Multiplexer Multiservice Transmission Platform User'Manual

IDM-300ME voice/audio optical multiplexer provide 2 shared 10/100Mpbs Ethernet interfaces, 6 transparently transmitted E1 interfaces and at most 300 FXO/FXS interfaces with “caller ID display” feature. IDM-300ME telephone MUX also provides 13 slots, which would be able to accommodate 1MCU (main control unit), 10 user’s units and 2 power units. All of these units support hot-swappable. IDM-300ME bandwidth is 155Mbps.
Contact Us

 

 

 

Multiservice Transmission Platform

 

User’s Manual

 

 

 

 

 

 

 

 

 

 

 

Apply to

IDM-300ME

Beijing Raytrans Digital Technology Co., Ltd

To the user

 

(1)                      Thank you for using our products. Within the scope of this equipment is used in design has a good and reliable performance, But still should avoid man-made damage to the equipment. Before using this product, read the user manual carefully, properly keep, Using for reference.

(2)                      Please check the model before installing this product, according to the requirements of user manual and installation

(3)                      Don’t make this product in the rain or be affected with damp in order to avoid damage

(4)                      Don't put anything on the power cable, don't put cable tie or encase.

(5)                      The power adapter, and other equipment shall be connected to each other tightly fitting

(6)                      Please note that the equipment clean, When necessary, can use soft cotton cloth to wipe.

(7)                      Please note that don't block ventilation cooling hole

(8)                      Please don't repair equipment, besides there is a clear instructions in the manual. When the equipment running abnormal please power off immediately and contact the company's after-sales service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multiservice Transmission Platform        

User’s Manual        

Apply to        

To the user        

1.        Overview        

2.        Main feature:        

3.        Structure of Equipment:        

4.        Device picture        

5.        Front and Rear panel        

5.1 Front panel        

5.2 Rear panels        

6.        Unit module description        

6.1 Port dispose unit module        

6.2 Power ringing current card (PRU)        

7.        Application        

8.        Interface specification        

9.        Installation and Setup        

9.1 Power access        

9.2 Fiber interface:        

9.3 Ethernet interface:        

9.4 Telephone business interface        

9.5 E1 interface:        

9.6 GND and PGND connection        

10. Equipment Common troubleshooting        

10.1 Optical alarm        

10.2 Ethernet don’t work        

10.3 Telephone don’t work        

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.       Overview 

DM-300ME voice/audio optical multiplexer provide 2 shared 10/100Mpbs Ethernet interfaces, 6 transparently transmitted E1 interfaces and at most 300 FXO/FXS interfaces with “caller ID display” feature. IDM-300ME telephone MUX also provides 13 slots, which would be able to accommodate 1MCU (main control unit), 10 user’s units and 2 power units. All of these units support hot-swappable. IDM-300ME bandwidth is 155Mbps. Our device has multiple clock mode, can meet the demand of all kinds of application environment of the clock. IDM-300ME also has power and ringing current backup capabilities. Ensure the reliability of the transmission business greatly.

 

2.       Main feature:

Ø                      Provide 2*100M self-adaption Ethernet interface, support automatic negotiation way, can work on full duplex/half-duplex, Ethernet port support exchange function, Save line resources effectively.

Ø                      IDM-300ME provide 10 user slots, each slot can access 30 channels 64K voice business, max provide 300 channels telephone.

Ø                      Provide 6 channels  transparent transmission E1 interface. 4 channels is 120Ohm, 2 channels is 75Ohm.

Ø                      Clock mode can set master clock, external clock , lines clock, user clock etc multi clock mode. Can work on DTE and DCE mode, Can satisfy users in multiple places (synchronous/asynchronous) demand of bandwidth and clock

Ø                      Optical port rate is 155Mbps, transmission distance is more than 20KM

Ø                      Perfect monitoring alarm function, provide Line optical disappeared, out-of-frame, E3, E6 etc alarm function. Indicator light can show alarm status, of course our equipment can output the alarm information

Ø                      With concise and perfect network management function, the system can monitor the network equipment real-time state, provide device configuration, fault statistics management, etc. remote alarm can be transferred to center office and output. Network management interface is RS232 interface.

Ø                      Our equipment is standard 6U chassis.

Ø                      DC-48V power supply.

Ø                      Perfect after-sales service system, provide three years of quality assurance and lifelong maintenance service.

 

3.       Structure of Equipment:

IDM-300ME include PCM optical transmission, E1 time slot cross connection inside the equipment. The main functions of the comprehensive reuse part is 300 various voice user interface. Can realize user interface time slot cross configuration with the network management software.

Based on the working principle of E1 reuse part

img1

 

4.       Device picture

img2

IDM-300ME front panels

 

img3

IDM-300ME rear panels

5.       Front and Rear panel

5.1 Front panel

Front panel is made up of FXO/FXS card, CMU card and PRU card.

CMU indicator light:

ACT: Flash, show CPU work well.

POW: ON, show -48V, +5V work well.

LOF1~LOF8: ON, Input signal frame loss, CRC set different, master-slave clock setting error, etc usually.

E-3: ON, optical line error E-3

E-6: ON, optical line error E-6

LINK2~LINK2: NET1-NET2 interface connect indicator light

SPEED1/SPEED2: NET1-NET2 transfer rate indicator light, ON, show transfer rate is 100Mbps.

FULL: ON, NET1-NET2 work mode full duplex

 

FXO/FXS indicator light:

POW: ON, this card +5V power work well.

1-30 indicator light show 1-30 user work statue

 

PRU indicator light:

POW: ON, show DV-48V/+5V power work well.

5V Fail: twinkle, 5V not work well.

Ring Fail: twinkle, Ring break down

 

5.2 Rear panels

P1-P8: Telephone interface

INA~IND/OUTA~OUTD: 4 channels E1 input/output interface.

NA1/NB1: Transparent transmission E1 interface.

COM: serial port

NET: Reserved interface

 

Power lines:

PGND: Protected Area

GND: power supply working

-48V: -48V input

 

6.       Unit module description

6.1 Port dispose unit module

CMU user control management module dispose 300 channels voice signal, monitor 5 types alarm status: NOP, LOF, LOS, E-3 alarm, E-6 alarm etc. also have Ethernet port status indicator light, alarm block switch, host reset switch etc.

 

Local management functions

Ø                      Provide internal communication bus interface to the user card, Used to regularly update each user plate status for all users, Will be distributed network management system configuration information for each channel to different users

Ø                      Provide network management channels in multi IDM-300ME device. Use to network management system manage and monitoring remote office IDM-300ME.

Ø                      Receiving network management system information, send center office/remote office alarm and user card status to network management system as the order.

Ø                      CPU status indicate, reset circuit and alarm sound shielding switch.

Ø                      Can set office center office or remote office

Network management interface manage function. IDM-300ME provide network management interface connect PC platform, can provide function as follow:

Ø                      Receiving and returning local site user status, 64Kb/s time slot chain status, power supply status.

Ø                      Receiving, transmit and return remote site IDM-300ME status.

Ø                      Receiving network management system configuration information for the local site CMU and user card.

Ø                      Receiving and transmit network management system configuration information for the remote site CMU and user card.

 

6.2 Power ringing current card (PRU)

PRU provide +5V, -5V power for the system. Indicate and report power supply work status.

Provide power status indicator light, serial port indicator light, -5V fault indicating light, -75V ringing current fault indicating light.

 

7.       Application

1

8.       Interface specification

Optical interface

Interface type

FC/SC

Fiber mode

Single/multi mode

Rate

155Mbps

Wavelength

850nm/1310nm/1550nm

Power

-2-11dBm

Sensitivity

Better than -36dBm

 

Ethernet interface

Interface type

RJ45

Rate

100Mbps,

Protocol standard

IEEE-802.3u

Interface mode

10/100M auto-negotiation

 

E1 interface

Code rate

2048Kbps

Code type

HDB3

Protocol standard

ITU-T G.703

Impedance

75Ω/120Ω

Frame structure

PCM30/31

Mode

EAP over Radius

 

FXO/FXS Interface

Audio frequency range

300Hz ~ 3400Hz

Impedance

200Ω+560Ω//0.1μF

Compression ratio

class A in ITU G.711

Loop current

25mA

 

FXO card

Ø                      FXO card is used to User voice signal and ST - BUS motherboard signal transformation; Subscriber line state signal and digital signal conversion between; And provide identification and status information to network management.

Ø                      FXO card is mainly used in automatic connection user telephone exchange, common battery telephone exchange interface. Usually used with FXS.

Ø                      FXO card support “Caller ID Display” When the telephone ringing corresponding light is on.

Ø                      FXO card provide 30 channels telephone business.

FXS card

Ø                      FXS card is used to User voice signal and ST - BUS motherboard signal transformation, feed to the telephone users, overvoltage and overcurrent protection, Called to the user when the fluid flow, Monitor users pick hang up, Subscriber line state signal and digital signal code conversion, And provide identification and status information to network management.

Ø                      FXS card can be used for automatic telephone billing, common battery telephone, billing telephone etc remote phone interface.

Ø                      FXO card support “Caller ID Display” When the telephone ringing corresponding light is on.

Ø                      FXO card provide 30 channels telephone business. 

 

 

Size:

IDM-300ME is standard 1U 19’inch chassis: length*width*height 482mm*266mm*280mm

Power Consumption:

Consumption: 200W±10%

 

9.       Installation and Setup

9.1 Power access

Power switch is OFF status, our device is DC-48V power supply. When connect power well, power switch set ON status, the light on the panel is POW, ALM, NOP red light is ON, other light is OFF.

1.jpg

DC power supply: DC48V-48V±5%

-48V: Connect DC-48V Power

GND: Connect power supply working

PGND: Connect Protected Area

9.2 Fiber interface:

Fiber access port is TX, RX. Default configuration is FC, RX connect the other site TX, TX connect the other site RX. Transmission distance is more than 20KM, can customization 40KM, 60KM.

9.3 Ethernet interface:

IDM-300ME provide 2 channels 100M Ethernet interface, interface type is RJ45, Business cable is standard Ethernet cables. Connect switch is shoot-through Ethernet cables, connect PC is cross Ethernet cables.

 

 

 

 

 

 

 

568A

White Green

Green

White orange

Blue

White Blue

Orange

White Brown

Brown

568B

White orange

Orange

White Green

Blue

White Blue

Green

White Brown

Brown

zhilian.jpg

Direct connection diagram

 

jiaolian.jpg

Crossing line diagram

 

9.4 Telephone business interface

IDM-300ME telephone business interface is 96PIN European-style socket

img8

Main

Auxiliary 

Blue

Orange

Green

Brown

Grey

Remark

White

1st

2nd

3rd

4th

5th

binding wire is white blue

Red

6th

7th

8th

9th

10th

Black

11th

12th

13th

14th

15th

Yellow

16th

17th

18th

19th

20th

Purple

21th

22th

23th

24th

25th

White

26th

27th

28th

29th

30th

binding wire is white orange

 

9.5 E1 interface:

IDM-300ME provide 6E1 NA1, NB1, INA~INB/OUTA~OUTB, INC~IND/OUTC~OUTD transparent transmission. INA~INB/OUTA~OUTB and INC~IND/OUTC~OUTD provide 2E1 transparent transmission via CC3-4 connector,

NA1/NB1 PIN sequence is as follow:

RJ45

Definition

Remark

1

OUT

First E1

2

GND

3

IN

4

GND

5

OUT

Second E1

6

GND

7

IN

8

GND

 

9.6 GND and PGND connection

(1). Both site connection, IDM-300ME and user equipment both connect group, resistance to ground is less than 0.3Ohm

2

(2) One site connection, IDM-300ME or user device connect group, resistance to ground is less than 0.3Ohm

img10

IDM-300ME and user device don’t connect group

img11

 

10. Equipment Common troubleshooting

10.1 Optical alarm

Optical alarm light: NOP light indicate equipment don’t reception optical signal, LOF light indicate optical path out-of-frame, RAI light indicate another site equipment alarm. According to the alarm indicator light alarm indicator can quickly optical path fault judgement.

l       Check the fiber contact with the equipment are well, Optical fiber plugs on both ends and devices to reconnect mouth in order to protect the connection is good

l       Optical fiber to reconnect after warning light still have the alarm, need to run out of power meter measuring optical fiber ends the sending power and receiving power of the plate; If send power normal end plate, and the receiving optical power is unusual then is fiber; If the plate shine power is very low, and can be judged to be plate problems

l       Optical plate sending power after normal use the tail fiber to this end equipment of light mouth, from the ring; If the warning light board since the ring is still warning lights, then the problem is the light board, If the warning light goes out after the ring you need to use the same method to test for the end of the light board. If the light on the end plate from the ring alarm lights are off, you can determine the fiber is problematic

l       When two devices are connected via a single fiber: First ends of the optical module is different, one end is 1310nm optical module, the other end is 1550nm optical module, also the transmission distance is different for example 20KM, 40KM, 60KM etc. When the two ends communicate with each other to ensure the end of the first identified as 1310nm, and the other end is identified as 1550nm, and secondly to ensure the same distance from both ends of the work identified in order to communicate

10.2 Ethernet don’t work

l                      First check the interface contacts are good and the network cable is connected to the Ethernet interface

l                      Check the cable: Check the pressure line RJ-45 meets the requirements of Ethernet cable, Check the cable line sequence is correct, Connected with the PC using a crossover cable, connected to the Ethernet switch using the straight-through

l                      Check the configuration on both sides of the PC is correct, whether in the same network segment, Correct preparation of both ends of the IP address, Working Group, Gateway etc.

10.3 Telephone don’t work

l                      Check the cable is connected to the telephone service interface PHONE

l                      Check the configuration of the device itself telephone line and the telephone service used to qualify whether the correspondence

l                      Equipment and cables connected to a corresponding interface connector is wired correctly

l                      When determining equipment business wiring accurate, please check the device Bureau remote connection is normal, central office equipment connected switches, remote devices connected telephones

l                      Finally, check the phone can work